SOLUTION

Plastic film blowing machine
Kinda VSD applied in platic film blowing machine


1, Load feature
  
  There are two parts on plastic film blowing machine can get energy saving:
  (1)  Power driven system, most of this part will install an additional frequency inverter, which make the main motor works at
         30~40Hz to get energy saving;
. (2)  Heating system, most of this part will install an electromagnetic heater to get energy saving.

2,  Requests for frequency inverters (VSD)
  (1)  Output high torque at low frequency.
  (2)  High speed control accuracy. (to avoid the raised grain occurs on the film).

3, Instruction for commissioning
(1)  Pictures of plastic film blowing machine


 
 

 
(2)  Parameters setting list (take 15kW, 5.5kW motor as example)

No.Function codesDefaultSetting valueExplanation
1F0-0201Start / stop by external signal15kW main motor
2F0-0311The motor speed is adjusted by keypad potentiometer.
3F0-17Model depend15sAcceleration time (adjustable)
4F0-10Model depend15sDeceleration time (adjustable)
5F0-120.02.0Torque boost (adjustable)

1F0-0201Start / stop by external signal5.5kW motor
2F0-0311The motor speed is adjusted by keypad potentiometer.
3F1-17Model depend15sAcceleration time (adjustable)
4F1-18Model depend15sDeceleration time (adjustable)


(3)  Typical wiring diagram


 
4, Notices
The temperature is always high on the site, pay attention to dust prevention and heat sink for frequency inverter.


seo seo